Boiler | Efficiency | Output | Warranty | MPN | Boiler Type |
---|---|---|---|---|---|
Ferroli BLUEHELIX RRT Tech 28kW Gas Combi Boiler | 94% | 28kW | 10 Years | Combi | |
Ferroli BLUEHELIX RRT Tech 24kW Gas Combi Boiler | 94% | 24kW | 10 Years | Combi | |
Ferroli BLUEHELIX RRT Tech 34kW Gas Combi Boiler | 94% | 34kW | 10 Years | Combi | |
Ferroli Domicompact F 30 B Gas Combi Boiler | 87.7% | 30kW | 1 Year | Combi | |
Ferroli i25 Gas Combi Boiler | 96.5% | 24kW | 2 Years | Combi | |
Ferroli i29 Gas Combi Boiler | 96.5% | 27kW | 2 Years | Combi | |
Ferroli iBoiler 25kW Gas Combi Boiler | 85% | 25kW | 2 Years | Combi | |
Ferroli iBoiler 29kW Gas Combi Boiler | 86% | 29kW | 2 Years | Combi | |
Ferroli maXima 35 C Gas Combi Boiler | 90.9 | 35kW | 1 Year | Combi | |
Ferroli maXima 35 S Gas Combi Boiler | 91% | 35kW | 1 Year | Combi | |
Ferroli Modena 27c HE Gas Combi Boiler | 90.3% | 27kw | 5 Years | Combi | |
Ferroli Modena 32c HE Gas Combi Boiler | 90.3% | 32kW | 5 Years | Combi | |
Ferroli Modena 38c HE Gas Combi Boiler | 90.3% | 38kw | 5 Years | Combi | |
Ferroli Optimax HE 31 C Gas Combi Boiler | 90.4 | 25kW | 5 Years | Combi | |
Ferroli Optimax HE 38 C Gas Combi Boiler | 90.5% | 30kW | 5 Years | Combi |
Boiler | Efficiency | Output | Warranty | MPN | Boiler Type |
---|---|---|---|---|---|
Ferroli BLUEHELIX RRT Tech 18kW Gas System Boiler | 94% | 18kW | 10 Years | System | |
Ferroli BLUEHELIX RRT Tech 24kW Gas System Boiler | 94% | 30kW | 10 Years | System | |
Ferroli BLUEHELIX RRT Tech 30kW Gas System Boiler | 94% | 30kW | 10 Years | System | |
Ferroli Modena 18s HE Gas System Boiler | 90.2% | 18kw | 5 Years | System | |
Ferroli Modena 25s HE Gas System Boiler | 90.4% | 25kw | 5 Years | System | |
Ferroli Modena 32s HE Gas System Boiler | 90.4% | 32kw | 5 Years | System | |
Ferroli Optimax HE 31 S Gas System Boiler | 90.6% | 30kW | 5 Years | System | |
Ferroli Optimax HE PLUS 18 s Gas System Boiler | 92.5% | 18kW | 5 Years | System | |
Ferroli Optimax HE PLUS 25s Gas System Boiler | 90.5% | 25kW | 5 Years | System |
Boiler | Efficiency | Output | Warranty | MPN | Boiler Type |
---|---|---|---|---|---|
Ferroli Optimax 25 OV Gas Regular Boiler | 90.4% | 25kW | 5 Years | Regular | |
Ferroli Optimax HE 18 OV Gas Regular Boiler | 92.5% | 18kW | 5 Years | Regular |
Fault Code | System Behaviour |
---|---|
A01 | Ignition error – possible electrode fault or power too low, no gas or excessive condensate level |
A02 | Electrode or card error |
A03 | Heating sensor damaged, no water circulation or air in system |
F04 | Wrong card parameter setting |
F05 | Air pressure switch contact error – wrong flue baffle obstructed or not correctly sized |
A06 | No flame after the ignition phase – low pressure in gas system burner minimum pressure setting |
F07 | Air pressure switch error – contacts closed on activation of fan |
A09 | Gas valve error – wiring could be disconnected or error with gas valve |
F10 | Delivery sensor error, sensor damaged wiring shorted or disconnected |
F11 | Domestic hot water (DHW) sensor error – sensor damaged, wiring shorted or disconnected |
A15 | Fault F05 generated 5 times within the last 24 hours – possible error with the air pressure switch |
A16 | Gas valve error – wiring disconnected or faulty gas valve |
A23 | Card parameter error – possibly wrong card parameter setting |
A24 | Card parameter error – possibly wrong card parameter setting |
F34 | Supply voltage under 170V – electric mains error |
F35 | Faulty mains frequency – electric mains error |
F37 | Error with system water pressure, possible pressure too low or water pressure switch is damaged |
F43 | Exchanger protection intervention – could be because no system water circulation or there’s air in the system |
F50 | Controller DBM23B error – controller could have an internal error |
F51 | Controller DBM23B error – controller could have an internal error |
Fault Code | System Behaviour | Possible cause |
---|---|---|
A01 | No burner ignition | No gas or ignition – issue with detection electrode, faulty gas valve or insufficient gas supply pressure |
A02 | Flame signal present with burner off | Electrode error or PCB error |
A05 | Fan error | No 230V power supply or tachometric signal interrupted fan damaged or out of balance |
A06 | No flame after the ignition phase | Ionisation electrode fault – flame unstable or air/flue ducts obstructed or condensate trap or pipes blocked |
F07 – F14 – A07 | High flue gas temperature | The flue gas probe detects excessive temperature |
F08 – A08 | Overtemperature protection intervention | Heating sensor damaged – no water circulation in the system or air in the system |
F09 – A09 | Overtemperature protection intervention | Return sensor damaged – no water circulation in the system or air in the system |
F10 – A10 | Flow sensor error | Sensor damaged – wiring shorted or wiring disconnected |
F11 – A11 | Return sensor fault | Sensor damaged – wiring shorted or wiring disconnected |
F12 | DHW sensor error | Sensor damaged – wiring shorted or wiring disconnected |
F13 – A13 | Flue probe fault | Probe damaged – wiring shorted or wiring disconnected |
A14 | Flue extraction duct safety device intervention | Fault F07 generated 3 times in the last 24 hours |
F34 | Supply voltage under 170V | Electric mains trouble |
F37 | Incorrect system water pressure | Pressure too low – water pressure switch either damaged, blocked or not connected |
F39 | Optional external probe error | Probe damaged or wiring shorted – probe disconnected after activating the outside temperature mode |
F41 | Activation of maximum ELTA T protection | Heating sensor damaged, return sensor damaged, no water circulation as air in the system |
F42 – A42 | Sensor control protection activation | Heating sensor damaged, return sensor damaged or disconnected |
F43 | Exchanger protection intervention | No system water circulation – air in system |
A23 – A24 – A26 – F15 – F20 – F21 – F40 – F47 – F50 – F51 – F53 | Printed circuit board (PCB) parameter fault | Wrong PCB parameter setting |
F56 – A56 | Calibration error / calibration procedure not completed | Incorrect parameters electrode damaged or not correctly positioned |
F61 – A61 | Printed circuit board (PCB) AGC01 error | PCB AGC01 internal error |
A54 – A55 – A63 | Printed circuit board (PCB) AGC01 fault | PCB AGC01 fault |
F67 | – | Boiler chip card (BCC) service key connected |
F68 – A68 | Boiler chip card (BCC) service key fault | Error loading BCC service key file |
A62 | No communication between PCB and gas valve | PCB not connected – valve damaged, replace valve |
A64 | Maximum number of consecutive resets exceeded | Maximum number of consecutive resets exceeded |
F66 | – | Firmware not loaded successfully |
Fault Code | System Behaviour |
---|---|
A01 | No burner ignition – possible electrode error, defective gas valve or incorrect inlet gas pressure |
A02 | Flame detected with the burner off – electrode defective main board defective |
A03 | High limit protection – possible flow temperature sensor not active or incorrectly located, no system circulation |
A04 | Flue gas fault – fault F07 happened 3 times in the last 24 hours |
A05 | Fan error – tachometer signal interrupted for 1 hour or longer |
A06 | No flame after the ignition phase – electrode error, flame unstable, incorrect valve gas offset or flue gas circuit obstructed |
A41 | Flow sensor error – sensor disconnected |
A42 | Flow sensor error – sensor damaged |
F07 | High fume temperature – the exchanger probe detects an excessive temperature |
F10 | Flow sensor error – sensor damaged, short circuited, sensor damaged or wiring broken |
F11 | Return sensor error – t-sensor damaged, short circuited, sensor damaged or wiring broken |
F13 | Exchanger probe error – t-sensor damaged, short circuited, sensor damaged or wiring broken |
F14 | Flow sensor error – t-sensor damaged, short circuited, sensor damaged or wiring broken |
F15 | Fan problem – tachometer signal interrupted fan connection or damaged debris in fan. You need to check and clean fan debris |
F34 | Supply voltage under 170v – electric supply error |
F35 | Irregular mains frequency – electric supply problem |
F37 | Incorrect system water pressure error – possible sensor damaged or pressure too low |
F43 | Exchanger protection activation – no system circulation air in system |
F52 | Flow sensor – fault sensor damaged |
A61 | Controller ABM03B error – controller has an internal error |
A62 | No communication between controller and gas valve – controller not connected or valve damaged |
A63 / A64 / F66 | Controller ABM03B error – controller internal error |
Fault Code | System Behaviour |
---|---|
A01 | No burner ignition – possibly no gas, detection or ignition electrode fault, defective gas valve, incorrect inlet gas pressure |
A02 | Flame detected with the burner off – possibly caused by ionisation, defective electrode or main board defective. Check the printed circuit board (PCB) or ionizing electrode wiring |
A03 | High limit protection – flow temperature sensor not active, incorrectly located or no system circulation. Check the position of the flow sensor or check pump and radiator valves |
A04 | Flue gas fault – could be because F07 happened 3 times in the last 24 hours – check the flue |
A05 | Fan problem – tachometer signal interrupted for 1 hour or longer – check the wiring and the fan |
A06 | No flame after ignition phase – possible causes: detection electrode fault, flame unstable, incorrect valve gas offset, flue gas circuit |
A41 | Flow sensor disconnected – check the correct positioning and operation of the flow sensors |
A42 | Flow sensor fault – sensor needs changing |
F07 | High fume temperature – the exchanger probe detects an excessive temperature for over 2 minutes – check the exchanger. |
F10 | Flow sensor fault – possible causes: sensor damaged, short circuited or wiring broken check the wiring |
F11 | Return sensor fault – sensor wiring shorted or broken – check the wiring |
F12 | Domestic hot water (DHW) sensor fault – sensor damaged, wiring shorted or wiring disconnected – check the wiring |
F13 | Exchange probe fault – wiring shorted or wiring broken – check wiring |
F14 | Fan problem – tachometer signal interrupted fan connection. Fan damaged or debris in fan – check the wiring, the fan and clean debris |
F15 | Supply voltage under 170v – electric supply problem – the electrical system needs checking |
F34 | Irregular mains frequency – possible electric supply problem – the electrical system needs checking |
F35 | Incorrect system water pressure – possible cause is pressure too low or sensor damaged – the system may need filling or check the sensor |
F37 | External probe fault sensor damaged or short circuited – check the wiring |
F39 | Exchanger protection activation – possibly caused by no system circulation, air in the system or sensor damaged |
F43 | Flow sensor fault – sensor damaged – sensor needs changing |
F52 | Controller 041049G0 fault – controller internal error |
A61 | No communication between controller and gas valve controller – could not be connected or valve damaged |
A62 | Controller 041049G – internal error |
A63 / A64 / F66 | Controller DBM12 fault |
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.