Elnur Boilers - Get Boiler Quotes

Elnur Boilers

Elnur Combi Boilers

BoilerEfficiencyOutputWarrantyMPNBoiler Type
ELNUR Mattira 10kW Electric Combi Boiler36.4%10kW2 YearsCombi
ELNUR Mattira 11kW Electric Combi Boiler36.4%11kW2 YearsCombi
ELNUR Mattira 12kW Electric Combi Boiler36.4%13kW2 YearsCombi
ELNUR Mattira 15kW Electric Combi Boiler36.4%15kW2 YearsCombi
ELNUR Mattira 3kW Electric Combi Boiler36.4%3kW2 YearsCombi
ELNUR Mattira 4kW Electric Combi Boiler36.4%4kW2 YearsCombi
ELNUR Mattira 5kW Electric Combi Boiler36.4%5kW2 YearsCombi
ELNUR Mattira 6kW Electric Combi Boiler36.4%6kW2 YearsCombi
ELNUR Mattira 7kW Electric Combi Boiler36.4%7kW2 YearsCombi
ELNUR Mattira 8kW Electric Combi Boiler36.4%8kW2 YearsCombi
ELNUR Mattira 9kW Electric Combi Boiler36.4%9kW2 YearsCombi

Elnur System Boilers

BoilerEfficiencyOutputWarrantyMPNBoiler Type
ELNUR Mattira 10kW Electric System Boiler36.4%10kW2 YearsSystem
ELNUR Mattira 11kW Electric System Boiler36.4%11kW2 YearsSystem
ELNUR Mattira 12kW Electric System Boiler36.4%12kW2 YearsSystem
ELNUR Mattira 13kW Electric System Boiler36.4%13kW2 YearsSystem
ELNUR Mattira 15kW Electric System Boiler36.4%15kW2 YearsSystem
ELNUR Mattira 3kW Electric System Boiler36.4%3kW2 YearsSystem
ELNUR Mattira 5kW Electric System Boiler36.4%5kW2 YearsSystem
ELNUR Mattira 6kW Electric System Boiler36.4%6kW2 YearsSystem
ELNUR Mattira 8kW Electric System Boiler36.4%8kW2 YearsSystem
ELNUR Mattira 9kW Electric System Boiler36.4%9kW2 YearsSystem
Fault Code System Behaviour
Boiler won’t start Power is not going to boiler. Possible central heating overheat switch tripped, DHW (domestic hot water) overheat switch tripped or DHW tank empty
E1 Heating water out temperature probe defective
E2 Heating water return temperature probe defective
E3 Low heating system pressure, pump not turning, air in system, system resistance too high or blocked
E6 Defective DHW tank temperature sensor
E8 Defective outdoor temperature sensor error or not present
Heating system water discharging from 3 bar safety valve Excessive heating system pressure
Domestic water discharging from 7 bar valve Excessive pressure in water system
The buttons do not respond Control panel blocked
Low heating temperature Settings too low, failure heating elements, heat requirements miscalculated
Fault Code System Behaviour Possible solution / cause
Boiler will not start No power to boiler, central heating overheat switch tripped Check incoming power supply and that boiler control switch is on
Fault E1 Heating water out temperature probe defective Contact an engineer
Fault E2 Heating water return temperature probe defective Contact an engineer
Fault E3 Low heating system pressure pump not turning, air in system, system resistance too high or blocked Replacement pump might be needed
Fault E8 Defective outdoor temperature sensor not present This sensor is optional, check connections & replace sensor if necessary, check parameter settings are correct
Heating system water discharging from 3 bar safety valve Excessive heating system pressure Check filling loop has not been left connected and is not letting water pass – disconnect filling loop hose & check expansion vessel
The buttons do not respond Control panel blocked Check 6.8 in user guide
Low heating temperature Settings too low, failure of heating elements, heat requirements miscalculated Check temperature and output selected – recalculate and configure